Background

Several factors are driving the growth of simulations. Computational power of computer clusters is growing, while the price of individual computers is decreasing. Distributed computing techniques allow hundreds, or even thousands, of computer nodes to participate in a single simulation. The benefit of this computational power is that simulations are getting more accurate and useful for predicting complex phenomena. The downside to this growth is the enormous amounts of data that need to be saved and analyzed to determine the results of the simulation. The ability to generate data has outpaced our ability to save and analyze the data. This bottleneck is throttling our ability to benefit from our improved computing resources. Simulations save their states only very infrequently to minimize storage requirements. This coarse temporal sampling makes it difficult to notice some complex behavior. To get past this barrier, ParaView can now be easily used to integrate post-processing/visualization directly with simulation codes. This feature is called co-processing in ParaView and the difference between workflows when using co-processing can be seen in the figures below.

Figure 15.1 Full Workflow
Figure 15.1 Workflow With Co-Processing


Technical Objectives

The main objective of the co-processing toolset is to integrate core data processing with the simulation to enable scalable data analysis, while also being simple to use for the analyst. The tool set has two main parts:

  • An extensible and flexible co-processing library: The co-processing library was designed to be flexible enough to be embedded in various simulation codes with relative ease. This flexibility is critical, as a library that requires a lot of effort to embed cannot be successfully deployed in a large number of simulations. The co-processing library is also easily-extended so that users can deploy new analysis and visualization techniques to existing co-processing installations.
  • Configuration tools for co-processing configuration: It is important for users to be able to configure the co-processor using graphical user interfaces that are part of their daily work-flow.

Note: All of this must be done for large data. The co-processing library will almost always be run on a distributed system. For the largest simulations, the visualization of extracts may also require a distributed system (i.e. a visualization cluster).

Overview

The toolset can be broken up into two distinct parts, the library part that links with the simulation code and a ParaView GUI plugin that can be used to create Python scripts that specify what should be output from the simulation code. Additionally, there are two roles for making co-processing work with a simulation code. The first is the developer that does the code integration. The developer needs to know the internals of the simulation code along with the co-processing library API and VTK objects used to represent grids and field data. The other is the user which needs to know how to create the scripts and/or specify the parameters for pre-created scripts in order to extract out the desired information from the simulation. Besides the information below, there are tutorials available.

Build Directions

As mentioned above, the two components for doing co-processing are a client-side plugin and a server-side library. It is recommended that they be compiled separately, but from the same ParaView source revision/release. This is because currently the client-side configuration tools outputs Python code for the server-side library to use. Differing ParaView versions may have different Python interfaces to objects causing simulation co-processed runs to fail.

ParaView Co-Processing Script Generator Plugin

The plugin for generating Python scripts for co-processing is a client-side plugin. The CMake option to turn-on the script generator plugin is PARAVIEW_BUILD_PLUGIN_CoProcessingScriptGenerator. Note: since this is a client-side plugin, the PARAVIEW_BUILT_QT_GUI option must be on.

Co-Processing Library

The directions for building the co-processing library can be a bit more complex. We assume that it will be built on a cluster or supercomputer. Complexities may arise from having to build Mesa, use off-screen rendering, build static libraries, and/or cross-compiling. We won't go into those details here, but refer interested people to the ParaView and VTK wikis.

The additional flags that should be turned on for coprocessing include:

  • BUILD_SHARED_LIBS: Should normally be set to ON unless you're compiling on a machine that doesn't support shared libs (e.g. IBM BG/L).
  • PARAVIEW_ENABLE_PYTHON: Set to ON in order to use the scripts created from the co-processing plugin. Note: For the 3.10 release, this is not required to be on.
  • PARAVIEW_USE_MPI: Set the ParaView server to use MPI to run in parallel. Also, check that the proper version of MPI is getting used.
  • CMAKE_BUILD_TYPE: Should be set to Release in order to optimize the ParaView code.
  • PARAVIEW_ENABLE_COPROCESSING: The CMake option to build the co-processing libraries.
  • BUILD_COPROCESSING_ADAPTORS: The CMake option to turn on code that may be useful for creating the simulation code adaptor.
  • BUILD_FORTRAN_COPROCESSING_ADAPTORS: The CMake option to turn-on code that may be useful for creating an adapter for a simulation code written in Fortran or C.
  • PYTHON_ENABLE_MODULE_vtkCoProcessorPython: On by default.
  • BUILD_PYTHON_COPROCESSING_ADAPTOR: Experimental code.

If ParaView was build with python enabled, the co-processing library can be tested on the installed system with the CTest command ctest -R CoProcessing. The CoProcessingTestPythonScript test does an actual coprocessing run and the CoProcessingPythonScriptGridPlot and CoProcessingPythonScriptPressurePlot test verify the output is correct. There are parallel versions of the coprocessing runs as well that run with multiple processes.In addition, looking at the code for this test is a useful beginning point for learning to use the co-processing library.

If you are using Mesa, the following options should be used:

  • PARAVIEW_BUILD_QT_GUI: set to OFF
  • VTK_OPENGL_HAS_OSMESA: Set to ON.
  • VTK_USE_X: Set to OFF.
  • OSMESA_INCLUDE_DIR and OPENGL_INCLUDE_DIR: Make sure these are not set to the OpenGL directory location of the header files.
  • OSMESA_LIBRARY: Set this to the Mesa library.
  • OPENGL_gl_LIBRARY and OPENGL_glu_LIBRARY: These should not be set.

Refer to ParaView And Mesa 3D for more details on building with Mesa.

Running the Co-Processing Script Generator

After starting the ParaView client, go to Tools|Manage Plugins, highlight CoProcessingPlugin, and click Load Selected. Alternatively, if you expect to be using this plugin often, you can tell ParaView to automatically load it by clicking to the left of CoProcessingPlugin to expand the list and choose the Auto Load option. This will add a CoProcessing and Writers menu to the GUI.

Once the plugin is loaded, load a simulation result into ParaView that is similar to the run you wish to do co-processing with. Normally the result will be for a discretization of the same geometry and contain the same field variables (or at least all of the field variables you wish to examine) as the simulation grid that co-processing will be performed on. The only difference between these two grids will be that the grid used for the co-processing run will be at a much higher resolution. In the picture below, a pipeline is shown for a result from a PHASTA (A CFD code led by Ken Jansen at the University of Colorado) simulation of incompressible flow through an aortic aneurysm. The simulation results include the velocity and pressure fields, and was done on a grid with 235,282 cells and 45,175 points. It is important to use the same names for the field arrays as will be used in the grids the co-processing library will be working with. The filters specify which fields to use by their name and problems will occur if the filters cannot find the correct array. The pipeline computes the vorticity, takes 20 slices through the domain, and extracts the surface of the grid.

Figure 15.2 Phasta Pipeline

Once the pipeline is set-up, the writers must be added to use for the filters that results are desired from. This is done by selecting the appropriate writer to output the results from each desired filter. In this example, a ParallelPolyDataWriter is created for the Slice filter and the ExtractSurface filter. For the writer for the Slice filter we set the name of the file to be slice_%t.pvtp where %t will get replaced with the time step each time it is output. We also set the write frequency to be every fifth time step. Figure 15.3 below shows this.

Figure 15.3 Phasta Pipeline with Writers

Similarly, we do the same for the writer for the ExtractSurface filter but we want to use a different file name and we can set a different write frequency if desired.

Note that when we hit enter we get the error message Cannot show the data in the current view although the view reported that it can show the data. This message can be ignored and is already entered as a bug to fix in ParaView.

The final step is to go through the CoProcessing->Export State wizard to associate the grid with a name that the python script uses and specify a file name for the script. The steps are:

1. Export Co-Processing State Click Next to proceed.

2. Select Simulation Inputs Choose which grids to use by highlighting the grid and clicking Add, then click Next.

CpExport1.jpg

3. Name Simulation Inputs Click in the boxes under Simulation Name and change the name to what you have named the grid in your adaptor. Our convention is to use "input" for simulations with a single grid or multiblock data set.

CpExport2.jpg

4. Configuration We usually want the full data and not just a picture of the results so for this we leave "Output rendering components i.e. views" unchecked and just hit Finish.

NoRendering.png

If we do want to output images in addition to any writers we may have specified, check "Output rendering components i.e. views" and fill in the proper information. For image output with pseudo-coloring field data, the range may not be known ahead of time or it may change as the simulation proceeds. For these cases, the user can check the "Rescale to Data Range" to ensure that a reasonable scale is uses to color the data by. Note that this applies to all views to be consistent with ParaView. For situations where there are multiple views, the user can switch through the views to set output parameters for each individual view. The parameters are:

  1. Image Type: a list of the available image formats to output as that the user can select from.
  2. File Name: the user can specify the name of the outputted screen shot. Note that %t will be replaced by the actual time step in the output file name.
  3. Write Frequency: similar to outputting geometry, the user should specify how often the screen shot image will be generated.
  4. Magnification: an integer value for specifying how much to enlarge the outputted image.
  5. Fit to Screen: if the geometry is changing the user may not be able to properly position the camera for the desired screen shot. Checking this option will fit the geometry to screen before the screen shot is taken. This is the same action as clicking on the PqResetCamera32.png icon in the ParaView GUI.
OutputRendering2.png

5. Save Server State: Specify the file name the script is to be saved as.

The resulting python script should look something like:

<source lang="python"> try: paraview.simple except: from paraview.simple import *

cp_writers = []

def RequestDataDescription(datadescription):

   "Callback to populate the request for current timestep"
   timestep = datadescription.GetTimeStep()


   if (timestep % 5 == 0) or (timestep % 200 == 0) :
       datadescription.GetInputDescriptionByName('input').AllFieldsOn()
       datadescription.GetInputDescriptionByName('input').GenerateMeshOn()


def DoCoProcessing(datadescription):

   "Callback to do co-processing for current timestep"
   global cp_writers
   cp_writers = []
   timestep = datadescription.GetTimeStep()
   grid5_0_vtu = CreateProducer( datadescription, "input" )
   
   GradientOfUnstructuredDataSet1 = GradientOfUnstructuredDataSet( guiName="GradientOfUnstructuredDataSet1", ScalarArray=['POINTS', 'velocity'], ResultArray

Name='Vorticity', ComputeVorticity=1, FasterApproximation=0 )

   Slice2 = Slice( guiName="Slice2", SliceOffsetValues=[-10.23284210526316, -8.8684631578947375, -7.5040842105263152, -6.1397052631578966, -4.77532631578947

43, -3.4109473684210529, -2.0465684210526316, -0.68218947368421201, 0.68218947368420935, 2.0465684210526316, 3.4109473684210521, 4.7753263157894743, 6.139705 263157893, 7.5040842105263152, 8.8684631578947375, 10.23284210526316, 11.597221052631578, 12.961600000000001], SliceType="Plane" )

   SetActiveSource(GradientOfUnstructuredDataSet1)
   ExtractSurface1 = ExtractSurface( guiName="ExtractSurface1", PieceInvariant=1 )
   
   SetActiveSource(Slice2)
   ParallelPolyDataWriter3 = CreateWriter( XMLPPolyDataWriter, "slice_%t.pvtp", 5 )
   
   SetActiveSource(ExtractSurface1)
   ParallelPolyDataWriter2 = CreateWriter( XMLPPolyDataWriter, "surface_%t.pvtp", 200 )
   
   Slice2.SliceType.Origin = [-2.8049160242080688, 2.1192346811294556, 1.7417440414428711]
   Slice2.SliceType.Offset = 0.0
   Slice2.SliceType.Normal = [0.0, 0.0, 1.0]
   


   for writer in cp_writers:
       if timestep % writer.cpFrequency == 0:
           writer.FileName = writer.cpFileName.replace("%t", str(timestep))
           writer.UpdatePipeline()

def CreateProducer(datadescription, gridname):

 "Creates a producer proxy for the grid"
 if not datadescription.GetInputDescriptionByName(gridname):
   raise RuntimeError, "Simulation input name '%s' does not exist" % gridname
 grid = datadescription.GetInputDescriptionByName(gridname).GetGrid()
 producer = TrivialProducer()
 producer.GetClientSideObject().SetOutput(grid)
 producer.UpdatePipeline()
 return producer


def CreateWriter(proxy_ctor, filename, freq):

   global cp_writers
   writer = proxy_ctor()
   writer.FileName = filename
   writer.add_attribute("cpFrequency", freq)
   writer.add_attribute("cpFileName", filename)
   cp_writers.append(writer)
   return writer

</source>

Creating the Adaptor

The largest amount of work in getting co-processing working with a simulation code is usually creating the adaptor that can pass a VTK data set or composite data set with fields specified over it. A simple view of the program control is

CoProcessorFlow.png

By doing it like this, there is minimal modification to the simulation code (only calls to the adaptor like Initialize, Finalize, and CoProcess). The adaptor deals with the coprocessing library as well as creating VTK data structures from the simulation code as needed. The general flow for the simulation code and where it calls the adaptor would look like:

 initialize coprocessor
 for i in number of time steps
   compute simulation information at time step i
   call coprocessing library
     coprocessing library determines if any coprocessing needs to be performed at time step i
 finalize coprocessor

The interactions between the adaptor and ParaView are mostly done through the vtkCPProcessor class. Documentation for this and the other classes in the coprocessing library are in the ParaView online documentation as well as grouped in a module. Details on the specific steps are provided below.

Initialize the Co-Processor

To initialize the co-processor, a vtkCPProcessor object must be created. This object should not be deleted until the finalization step. After creating a vtkCPProcessor object, you must call vtkCPProcessor::Initialize() to initialize the coprocessing library. The next step is to create vtkCPPipeline objects. These objects are used to represent the VTK pipelines that will be used to generate the output data. Most users will probably only use the vtkCPPythonScriptPipeline class that derives from vtkCPPipeline since that pipeline is the one that is used with the python scripts generated from the coprocessing plugin. vtkCPPythonScriptPipeline::Initialize() takes in the python script name with the full path and sets up the ParaView python interpretor.

Call the Co-Processor to Execute the Desired Filters

Most users will have a single call to the adaptor at the end of each simulation time step. This will pass in the simulation data structures to create the VTK data structures from. The created VTK data structures will be an object that derives from vtkDataObject. First though we want to check if we actually need to do any co-processing during this call. The simulation code will not know this information. Because of this, the simulation code should call the adaptor every time step. The adaptor gets the information about what data is needed for executing the vtkCPPipelines for each call. This is done in vtkCPProcessor::RequestDataDescription() by going through all of the vtkCPPipeline objects and querying them for what is needed. vtkCPProcessor::RequestDataDescription() takes in a vtkCPDataDescription object that contains information about the current simulation time and time step. The method returns 0 if no coprocessing information needs to be computed during the call and 1 otherwise. If no coprocessing needs to be performed then the adaptor should return control back to the simulation code.

If co-processing is requested then the adaptor needs to make sure that the VTK grids and fields are up to date. Upon return from vtkCPProcessor::RequestDataDescription(), the vtkCPDataDescription object will have information on what is needed by the pipelines in order to successfully execute them during this call to the adaptor. This information is stored for each co-processing input (the data objects that are given identifier names in the plugin) and accessed through the vtkCPDataDescription as vtkCPInputDataDescription objects. The vtkCPInputDataDescription objects specify whether or not they require a grid and if so which fields they require. These objects are also used to pass the VTK data objects created in the adaptor to the pipeline by using the vtkCPInputDataDescription::SetGrid() method. The final step in this call to the adaptor is then to perform the actual co-processing by calling the vtkCPProcessor::CoProcess() method.

Finalize the Co-Processor

Finalization entails calling vtkCPProcessor::Finalize() and cleaning up any remaining VTK objects by calling Delete();



While initially there may seem to be a significant hurdle to overcome in order to implement the adaptor for co-processing, the user only needs to know enough information to create the VTK data objects from their own simulation data structures. The adaptor can be made computationally efficient by taking advantage of intimate knowledge of the simulation code and knowing that VTK filters will not modify input data. Examples include:

  • Only creating the VTK grid in the first call to the adaptor if the grid is not changing topologically or geometrically.
  • Using the SetArray() method to build vtkDataArray objects that use existing memory used by the simulation code instead of allocating and copying existing memory.

Coprocessing Tutorials are also available for ParaView 3.14 and 3.98.

Finally, we suggest looking at either the C++ coprocessing example and/or the python coprocessing example to see how the entire co-processing flow works. Additonally, the code in ParaView3/CoProcessing/CoProcessor/Testing/Cxx/PythonScriptCoProcessingExample.cxx is also worth a look. This is used to test the co-processing library and can be run with the command "ctest -R CoProcessing".

Experimental: Reusing simulation memory

For large-scale simulations, the memory overhead of copying the simulation's data set into a VTK data object may be prohibitive. Recent work in VTK has added the ability to use external memory and data structures in the coprocessing pipeline. The vtkMappedDataArray and vtkMappedUnstructuredGrid classes may be subclassed for this purpose and used to map the simulation’s data into the vtkDataArray and vtkUnstructuredGridBase interfaces, respectively. Details of these interfaces, along with instructions for adapting existing filters and algorithms for use with them, can be found at this wiki page.